101
Syrup flavor
cross-over from
previous shake.
a. Draw handle was
closed manually.
a. Allow the sensor to close the draw valve. Do not manually
close the draw handle.
b. Syrup line is
restricted, pressure
in line.
b. Clean and sanitize the syrup line.
c. Syrup jug is empty,
air in line is
pushing syrup out
of the syrup valve.
c. Install a full syrup jug and prime the syrup line.
d. Air in syrup line,
syrup line
improperly primed.
d. Prime the syrup line.
e. Driven spinner is
worn, resulting in
flavored product
remaining in door
spout.
e. Replace the driven spinner.
Problem
Shake Side
Probable Cause
Soft Serve Side
Probable Cause.
Either Side Probable
Cause
Corrective Action