2. When the mix stops bubbling down into the freezing
cylinder, remove the cotter pin from the outlet fitting
of the mix pump.
Insert the outlet end of the mix feed tube into the mix
inlet hole in the mix hopper. Place the inlet end of the
mix feed tube into the outlet fitting of the mix pump.
Secure with cotter pin.
3. Select the Auto symbol
.
Note:
This procedure should be done 15 minutes before
product is expected to be served.
4. Fill the hopper with
fresh
mix and place the mix
hopper cover in position.
VFD SCREENS
The vacuum fluorescent display (VFD) located in the
center of the control panel is normally blank during the
daily operation of the machine. The display is activated
when the Calibrate symbol
or the Manager's Menu is
selected. The display screen will also alert the operator of
specific faults detected by the control.
Power Up
When the machine is powered, the control system will
initialize to perform a system check. There will be four
types of data the system will check when the control is
initializing: Lamp Test, Lockout Data, Configuration Data,
and System Data. (See Figure 169.)
Figure-169
Lamp Test: The control and software version is displayed
and all of the LEDs on the display panel are illuminated.
(See Figure-170.)
Figure-170
Following the lamp test, three separate screens will
appear during initialization.
During the Initializing . . . . . if the system detects corrupt
data, the following display will alert the operator that the
control settings have changed (see Figure-171):
Figure-171
Once the system has initialized, the number of days
remaining before the next required brush-cleaning is
indicated on the control panel, and the SAFETY
TIMEOUT screen is displayed with the alarm turned on.
(See Figure-172.)
Figure-172
The SAFETY TIMEOUT screen will be displayed with the
alarm on for 60 seconds or until any control symbol is
selected.
After the Safety Timeout has been completed and the
power switch is in the OFF position, the status screen will
display. When the brush-clean requirements have been
met, the following screen will display (see Figure-173):
Figure-173
If a brush-cleaning was not completed, the status screen
will display the current hopper temperature, barrel
temperature, and the 5-minute brush-clean timer.
Figure-174
Initializing . . . .
Lockout Data
Initializing . . . .
Config Data
Initializing . . . .
System Data
Summary of Contents for C602
Page 2: ......
Page 9: ...7 Front View Figure 2 1 2 3 4 5 7 7a 10 11 8 8 9 7c 7b 6 12 13 14 ...
Page 21: ...19 Beater Door Assembly Shake Side Figure 11 6 4 1 3 2 5 17 11 13 12 7 8 10 9 14 15 16 ...
Page 23: ...21 Beater Door Assembly Soft Serve Side Figure 12 2 3 11 4 5 12 13 1 14 15 16 6 8 7 6 9 10 ...
Page 25: ...23 X53800 BRN TAN Syrup Pump Figure 13 3 4 2g 5 1 2e 2f 2d 2c 2a 2b 2 2h ...
Page 114: ...057888 M ...