Shake draw valve is
not opening.
a. The power switch
is OFF.
a. Place the power switch in the ON position.
b. The shake side is
in the Standby
mode.
b. Cancel the Standby mode.
c. A Heat cycle is in
progress.
c. Wait for the completion of the Heat Treatment cycle.
d. The menu is
displayed, making
the flavor select
keys inoperative.
d. Exit the menu to restore the control keys to their normal
function.
e. The draw valve
wasn't aligned with
the actuator
bracket when the
freezer door was
installed.
e. Reassemble with the correct alignment. Tighten the
handscrews in a crisscross pattern when installing the
freezer door.
f. The draw valve
was not lubricated.
f. Lubricate the draw valve and O-rings.
g. The shake actuator
assembly is out of
alignment or is
malfunctioning.
g. Call a service technician.