32
Symbol Definitions
To better communicate in the international arena, the
words on many of the operator keys have been replaced
by symbols to indicate their functions. Your Taylor
machine is designed with these international symbols.
The following chart identifies the symbol definitions:
Power Switch
When placed in the ON position, the power switch allows
control panel operation.
Vacuum Fluorescent Display
The vacuum fluorescent display (VFD) is on the front
control panel. During normal operation the display is
blank. The display shows menu options and notifies the
operator if a fault is detected. On international
models, the display will indicate the temperature of the
mix in each hopper.
Indicator Lights
Mix Low
—When the Mix Low symbol
is illuminated,
the mix hopper has a low supply of mix and should be
refilled as soon as possible.
Mix Out—
When the Mix Out
symbol is illuminated,
the mix hopper has been almost completely exhausted
and has an insufficient supply of mix to operate the
freezer. At this time, the Auto mode is locked out and the
freezer will be placed in the Standby mode. To initiate the
refrigeration system, add mix to the mix hopper and
press the Auto symbol
. The freezer will automatically
begin operation.
Heat Mode Symbol
When the Heat mode symbol
is illuminated, the
freezer is in the process of a Heat cycle. The Heat mode
symbol may be selected to start a Heat cycle following a
freezer soft lock condition.
The heat treat key can be enabled/disabled via the
service menu to allow the manual start of Heat treat at
any time.
Brush-Clean Countdown
- Displays the number of days
before the next brush-cleaning is required. When the
display has counted down to 1, the machine must be
disassembled and brush-cleaned within 24 hours.
=
Auto
=
Heat Cycle
=
Wash
=
Mix Pump
=
Standby (Shake)
=
Standby (Soft Serve)
=
Flavor Selection
=
Mix Low
=
Mix Out
=
Topping Heater-Left
=
Topping Heater-Right
=
Calibrate
=
Menu Display
Summary of Contents for C602
Page 2: ......
Page 9: ...7 Front View Figure 2 1 2 3 4 5 7 7a 10 11 8 8 9 7c 7b 6 12 13 14 ...
Page 21: ...19 Beater Door Assembly Shake Side Figure 11 6 4 1 3 2 5 17 11 13 12 7 8 10 9 14 15 16 ...
Page 23: ...21 Beater Door Assembly Soft Serve Side Figure 12 2 3 11 4 5 12 13 1 14 15 16 6 8 7 6 9 10 ...
Page 25: ...23 X53800 BRN TAN Syrup Pump Figure 13 3 4 2g 5 1 2e 2f 2d 2c 2a 2b 2 2h ...