85
The first screen displays the month and day of the Heat
cycle, the start time and end time, and the fault
description. The bottom line displays the record number
and indicates if a power failure occurred during the Heat
cycle (POWER FAILURE IN HC). (See Figure-224)
Figure-224
Select the Auto symbol
to advance forward through
the data pages. Select the optional Flavor symbol
to
reverse the page direction.
Hopper and barrel temperature records for each side of
the freezer are displayed in the second and third screens.
The second screen shows the left side (L) side of the
freezer. (See Figure-225) The third screen shows the
right side (R) of the freezer. (See Figure-226).
The top line of these screens shows the hopper (H) and
barrel (B) temperatures recorded at the end of the Heat
Treat cycle and indicates the side (L or R) of the freezer.
The remaining lines indicate the following:
HEAT =
Total time for the hopper (h) and barrel (b) to
reach 150.9°F (66.1°C).
OVER =
Total time the hopper (h) and barrel (b)
temperature was above 150°F (65.6°C).
COOL =
Total time the hopper (h) and barrel (b)
temperature was above 41°F (5°C) during the Cool
phase.
PEAK =
Highest temperature reading for the hopper (h)
and barrel (b) during the Heat Treatment cycle.
Figure-225
Figure-226
The Heat time indicates the amount of time taken in each
zone to reach 150.9°F (66.1°C). Each zone must remain
above 150°F (65.6°C) for a minimum of 35 minutes. In
addition, each zone must be heated for a minimum of 115
minutes.
Select the Auto symbol
to advance to the next page,
or the optional Flavor symbol
to view the previous
page.
A Heat cycle failure message will display on the first
screen if a failure occurred.
Listed below are variable failure code messages which
could appear on line 2:
HT
HEAT TIME FAILURE
Mix temperature did not rise above 151°F
(66.1°C) in less than 90 minutes.
CL
COOL MODE FAILURE
Mix temperature in the hopper and freezing
cylinder did not fall below 41°F (5°C) in less
than 120 minutes.
TT
TOTAL TIME FAILURE
The Heat Treatment cycle must be
completed in no more than 6 hours.
MO
MIX OUT FAILURE
A Mix Out condition was detected at the start
or during the Heat cycle.
ML
MIX LOW FAILURE
The Heat phase or Cool phase time was
exceeded and a Mix Low condition was
present.
BO
BEATER OLVD IN HC
A beater overload occurred during the Heat
cycle.
HO
HPCO IN HEAT CYCLE
A high-pressure cut-out condition occurred
during the Heat cycle.
PF
POWER FAILURE IN HC
A power failure caused the Heat phase, Cool
phase, or Total Cycle Time to exceed the
maximum allowed time. If a power failure
occurs but the Heat Treatment cycle does
not fail, an asterisk(*) will appear on the third
line of the display.
PS
POWER SWITCH OFF
The power switch was placed into the OFF
position during the Heat cycle.
TH
THERMISTOR FAILURE
A thermistor probe has failed.
OP
OPERATOR INTERRUPT
Indicates the Heat cycle was aborted by the
OPERATOR INTERRUPT option in the
Service Menu.
PD
PRODUCT DOOR OFF
A product door is not in place or is loose.
Summary of Contents for C602
Page 2: ......
Page 9: ...7 Front View Figure 2 1 2 3 4 5 7 7a 10 11 8 8 9 7c 7b 6 12 13 14 ...
Page 21: ...19 Beater Door Assembly Shake Side Figure 11 6 4 1 3 2 5 17 11 13 12 7 8 10 9 14 15 16 ...
Page 23: ...21 Beater Door Assembly Soft Serve Side Figure 12 2 3 11 4 5 12 13 1 14 15 16 6 8 7 6 9 10 ...
Page 25: ...23 X53800 BRN TAN Syrup Pump Figure 13 3 4 2g 5 1 2e 2f 2d 2c 2a 2b 2 2h ...
Page 114: ...057888 M ...