103
Shake is filling too
high in cup.
a. Sensor shield is
obstructed, unable
to detect
temperature
change.
a. Clean the sensor shield.
b. Cup holder not
installed all the
way; cup too far
away from sensor.
b. Install the cup holder all the way to the panel.
c. Shake is too cold/
thick, caused by
improper syrup
calibration.
c. Properly calibrate the syrup.
d. Shake is too cold/
thick, caused by
improper priming.
d. Reprime the freezing cylinder.
e. Syrup is too cold/
thick, caused by
mix pump
malfunction.
e. Clean the mix pump. Inspect and replace wear items.
f. Syrup is too cold/
thick, caused by
incorrect viscosity
setting.
f. Call a service technician.
g. Defective fill
sensor.
g. Call a service technician.
Problem
Shake Side
Probable Cause
Soft Serve Side
Probable Cause.
Either Side Probable
Cause
Corrective Action