79
The
SYRUP CALIBRATION
option allows the manager
to access the calibration screen selections from the
Manager's Menu. The same functions found in the
Calibration menu are displayed on the screen when this
menu option is selected. (See “Syrup System” on
page 39.)
Figure-193
Note:
The UNFLAVORED DRAW option will only appear
on the screen when the shake side is in the Auto mode.
The
VERIFY CALIBRATION
option is used to verify that
the amount of syrup dispensed is within the proper
specification. (See Figure-194)
Figure-194
Remove the syrup valve from the dispensing door. With
the line fully primed with syrup, position the syrup valve
over the small chamber side of the divided syrup cup.
Then select the corresponding flavor selection. Syrup will
flow into the cup for 5 seconds (7 seconds for triple thick
shake syrup), and then automatically stop flowing. Place
the cup on a flat surface and check the amount of syrup
dispensed. If the level is not within the correct
specification, the flavor will need to be recalibrated.
(See “Syrup Calibration” on page 39.)
It is recommended to verify the calibration of each syrup
flavor and note any flavors that need to be recalibrated
before exiting the Manager's Menu to access the
Calibration Menu.
Select the Calibrate symbol
to exit the VERIFY
CALIBRATION screen and return to the Manager's Menu
list.
The
SERVINGS COUNTER
screen is used to check or
reset the number of servings dispensed from the
machine. (See Figure-195.)
Figure-195
Reset the SERVINGS COUNTER by selecting the AUTO
symbol
to move the arrow to Next. The Reset
Counters and Details selections will be displayed on the
next screen. (See Figure-196.)
Figure-196
Select the Auto symbol
to move the arrow to Reset
Counters. Then select the Calibrate symbol
.
(See Figure-197.)
Figure-197
The display will ask, Are you sure? To reset the counters,
select the Auto symbol
to move the arrow to Yes.
Select the Calibrate symbol
to clear the left and right
counters and return to the SERVINGS COUNTER
screen. If you do not want to clear the serving counter,
move the arrow to No and select the Calibrate symbol
to return to the SERVINGS COUNTER screen without
resetting the counters to zero.
Note:
The Servings Counter will automatically reset to
zero when the machine is brush-cleaned.
(See Figure-198.)
Figure-198
Access the Details screen by selecting Next in the
SERVINGS COUNTER screen. Move the arrow to
Details, and then select the Calibrate symbol
.
(See Figure-199.)
Figure-199
Summary of Contents for C602
Page 2: ......
Page 9: ...7 Front View Figure 2 1 2 3 4 5 7 7a 10 11 8 8 9 7c 7b 6 12 13 14 ...
Page 21: ...19 Beater Door Assembly Shake Side Figure 11 6 4 1 3 2 5 17 11 13 12 7 8 10 9 14 15 16 ...
Page 23: ...21 Beater Door Assembly Soft Serve Side Figure 12 2 3 11 4 5 12 13 1 14 15 16 6 8 7 6 9 10 ...
Page 25: ...23 X53800 BRN TAN Syrup Pump Figure 13 3 4 2g 5 1 2e 2f 2d 2c 2a 2b 2 2h ...
Page 114: ...057888 M ...