92
The product is too
soft.
a. Too much syrup.
Non-TTS: 1 fl. oz.
(30 ml) in 5
seconds. For triple
thick shake syrup:
1 oz. (30 ml) ±1/8
oz. (4 ml) in 7
seconds.
a. Calibrate the syrups.
b. Draw rate is set
too fast.
b. Adjust draw rate of 5 oz. to 7-1/2 oz. (142 g to 213 g) of
product by weight in 10 seconds.
c. Outdrawing capacity of
the freezing cylinder.
c. Allow the machine to recover and cycle off before drawing
more product.
d. Air passage blocked in
pump.
d. Brush-clean pump components and reassemble.
e. Inadequate airspace.
e. Minimum of 3 in. (76 mm) airspace on all sides, with the
deflector installed to prevent recirculation of warm air.
f. Dirty condenser or air
filters on air-cooled
machines.
f. Check/replace filters regularly.
g. Inadequate water
supply on water-cooled
machines.
g. Check the water supply. Check the water lines for leaks or
kinks.
h. Worn or damaged
scraper blades.
h. Replace the scraper blades.
i. The viscosity control is
set too warm.
i. Call a service technician.
Problem
Shake Side
Probable Cause
Soft Serve Side
Probable Cause.
Either Side Probable
Cause
Corrective Action