11. Remove the syrup nose fitting from the syrup valve
by turning the cap counterclockwise.
12. Remove the duckbill valve and O-ring from the syrup
nose fitting.
13. Using the white end of the double-ended brush,
scrub the inside of the syrup nose fitting and the
syrup line fitting to remove any residual particles.
14. Using a shake cup filled with KAY-5
®
Sanitizer
(HCS), rinse the syrup valve fitting thoroughly.
15. Using a clean, sanitized towel, gently wipe any syrup
from the duckbill valve.
16. Install the duckbill valve into the syrup nose fitting
with the flat end aligned with the open slot in the
syrup nose fitting.
Note:
Replace the duckbill valve if it is damaged or
extends past the syrup nose fitting slot. (See Figure-70.)
Figure-70
17. Install the syrup nose fitting onto the syrup line fitting.
Tighten by hand until secured.
Note:
The
duckbill valve must be wet
when the syrup
nose fitting is assembled on the syrup line fitting. The
sanitized water will lubricate the bottom flat surface and
prevent the duckbill from twisting when the syrup nose
fitting is tightened.
18. Inspect the duckbill valve for proper installation inside
the syrup nose fitting. The tip of the duckbill valve
must be flat
to seal the syrup line. (See Figure-71.)
Figure-71
If the tip is not flat, remove the syrup nose fitting and
remove/re-install the duckbill valve. Using a shake
cup filled with sanitizing solution, rinse the syrup
nose fitting to wet the bottom of the duckbill valve.
Re-install the syrup nose fitting onto the syrup line
fitting. If the tip will not remain flat when the syrup
fitting is assembled, replace the duckbill valve.
19. Install the O-ring on the syrup nose fitting.
20. Repeat steps 3 through 19
for all syrup flavors.
21. Remove the pickup tubes from the pail of
KAY-5
®
Sanitizer (HCS) and allow them to drain.
22. Place all the pickup tubes into the syrup containers.
Ensure the syrup lines match their respective flavors.
For Syrup Bag System:
Attach the bag connector
fitting to the proper syrup flavor.
23. Select the Calibrate symbol
on the control panel
to display the menu options.
24. Press the Auto symbol
to move the arrow to
SYRUP PRIME. Press the Calibrate symbol
again to display the SYRUP PRIME screen.
25. Select the Flavor Selection symbol
for the
corresponding syrup valve to start the flow of syrup.
26. Allow the syrup to flow until all of the KAY-5
®
Sanitizer (HCS) and air is purged from the line.
27. Press the Flavor Selection symbol
to stop the
flow of syrup.
28. Lubricate the O-ring on the syrup nose fitting. Install
the syrup valve into the shake door and secure the
valve by lowering the retainer.
29.
Repeat steps 21 through 28
for all syrup flavors.
Summary of Contents for C602
Page 2: ......
Page 9: ...7 Front View Figure 2 1 2 3 4 5 7 7a 10 11 8 8 9 7c 7b 6 12 13 14 ...
Page 21: ...19 Beater Door Assembly Shake Side Figure 11 6 4 1 3 2 5 17 11 13 12 7 8 10 9 14 15 16 ...
Page 23: ...21 Beater Door Assembly Soft Serve Side Figure 12 2 3 11 4 5 12 13 1 14 15 16 6 8 7 6 9 10 ...
Page 25: ...23 X53800 BRN TAN Syrup Pump Figure 13 3 4 2g 5 1 2e 2f 2d 2c 2a 2b 2 2h ...
Page 114: ...057888 M ...