100
Spinner shaft will not
rotate to blend mix
and syrup.
a. Spinner motor is
out on thermal
overload.
a. Allow the spinner motor to cool. Check lubrication on the
spinner shaft.
b. Pin is missing in
quick disconnect of
spinner coupling.
b. Call a service technician.
c. Flexible coupling is
broken.
c. Call a service technician.
Finished shake
improperly blended;
has blotchy/striped
appearance.
a. Driven spinner is
worn, white spinner
not secured in
bottom of draw
valve.
a. Replace the spinner.
b. Spinner shaft
coupling defective
or not adjusted to
correct height.
b. Adjust or replace the coupling.
c. Shake is too cold/
thick.
c. Recalibrate syrup.
d. Viscosity setting is
too high.
d. Call a service technician.
Problem
Shake Side
Probable Cause
Soft Serve Side
Probable Cause.
Either Side Probable
Cause