SW4000 USER’S MANUAL
68 VER5.13
datum function; otherwise to resume the datum by RI is unable.
STEPS:
1. Enter “SETUP”, then press
or
until the
message window displays “ALL CLS”;
2. Press
ENTER
and message windows display “PASSWORD”
indicating the operator to input password. At this moment,
there are two selections:
A Press
AC
to quit “ALL.CLS”;
B Enter the correct password to clear all
parameters and load default setup;
3. Input the password;
Press
1
9
9
9
ENTER
in turn to load default value.
The message window displays “WAITING”, which means
the clearing is going on.
4. Return normal display state after loading default setup is
finished.
The default setup for all parameters is as following:
Counting direction is mode 0;
The R/D is mode R ;
Z DIAL = 2.5mm;
Resolution = 5
µ
m;
EDM mode is MODE 1;
Relay mode is mode 0;
Shrinkage ration 1.000;
Input mode in SDM as 0, display value = input value;
Deep compensation is disabled;
Lathe function is disabled;
Slope machining parameter is Z step;
RI MODE is mode 8;
Disable the edge detection;
Linear scale is installed for any axis;
Angle display mode is mode 1: 0~360;