SW4000 USER’S MANUAL
60 VER5.13
Example: Set SDM mode 1.
1. Enter “SETUP”, then press
or
until the
message window displays “SDM DIR”;
2. Press
ENTER
,
Y window displays the former SDM mode;
3. Press
1
to set the SDM mode 1;
NOTE: press
0
to set the SDM mode 0.
4. Press
ENTER
to confirm your setting and exit
“SDM.MODE”.
Press
AC
to cancel your change and exit “SDM.MODE”.
7.11
Enable / Disable ERROR Signal
SW4000 serial DRO provides the function of checking whether the counting signal is normal or not.
It can display the ERROR information if some error occurs in counting signal. User can enable or disable
this function.
“0” means no error information will be displayed and the DRO continue to work when there is some
wrong with linear scale or encoder:
“1” means error information will be displayed when error occurs.
Default setting: 0 (disable display error message).
Example: Enable display ERROR message.
STEPS:
1. Enter “SETUP”, then press
or
until “ERROR”
appears in message window;
2. Press
ENTER
,
Y window displays the former “0”;
3. Press
1
to change it to enable error message;
Note: press
0
to change to disable error message.