SW4000 USER’S MANUAL
58 VER5.13
4. Press
or
to scroll through 0.05, 0.10, 0.20, 0.50,
1.00, 2.00, 5.00, 10.00, 20.00, 5 0.00. Press
ENTER
to
select “1.00” when it appears and return “SEL.RXIS” state.
Press
AC
to cancel your selection.
5. Set the resolution of Y axis: Z axis by repeating step 3-4.
6. Press
ENTER
to exit “RESOLUTE” setup.
7.8
Setting Relay Mode
The relay will send out an ON/OFF signal when
process to target position. EDM.Relay interface has
three pins: common, normal close and normal
open.SW4000E provides four Relay modes. Operator
can set it according to your circuit.
Normal close and common pin:
RELAY MODE
Power ON
ENTER EDM
PROCESS TO
TARGET POSITION
EXIT EDM
Power off
1
close
close
open
close
open
2
open
open
close
open
open
3
close
open
close
close
open
4
open
close
open
open
open
Default value: MODE 2.
STEPS:
1. Enter “SETUP”, then press
or
until the
message window displays “RELAY.MOD”;
2. Press
ENTER
, then the Y window displays “0” or “1”;
COLOR
NC
4
9
6
5
IN-
IN+
NORMAL
OPEN
PIN
NAME
2
3
1
COMMON
NORMAL
CLOSE
NC
BLK
YEL
RED
ORG
BRW