SW4000 USER’S MANUAL
66 VER5.13
For example, set the mode as STEP mode.
STEPS:
1. Enter “SETUP” and press
or
until the message
window displays “STEP. MODE”;
2. Press
ENTER
,
Y window displays the former setting.
“0” means Z STEP;
“1” means MAX CUT;
The message window displays “SEL MODE” , which means
selecting step mode of ARC next step.
3. Set mode as STEP mode.
Press
1
, then Y window displays the changed mode.
4. Press
ENTER
to confirm your change and exit “STEP.MODE”.
Press
AC
to cancel your new set and exit.
7.20
Angle Display Mode
SW4000 provides 3 angle display modes. In Mode 1, the angle is in the range of 0
°
to 360
°
; in mode 2,
the angle is in the range of -360
°
to 360
°
; and in mode 3, the angle is in the range of -180
°
to 180
°
.
Default mode: MODE 1.
Set the EDM mode as mode 2.
STEPS:
1. Enter “SETUP”, then press
or
until message
window displays “ANGL. MODE”;
2. Press
ENTER
, then Y window displays the former angle
mode;
The message window displays “SEL MODE” , which means
to select angle display mode next step.
3. Set the angle display mode as mode 2.
Press
2
then the Y window displays the changed mode;