3. Select axis;
Press
X
to change RI mode of X axis. The number in X
window flashes;
Press
Y
to change RI mode of Y axis, and the data in Y
window flashes;
Press
Z
to change RI mode of Z axis, and the data in Z
window flashes;
4. Press
or
, then “1”, “2”, “3”, “4”, “5”, “6”, “7”,
“8” will be displayed in turn;
When “5” is displayed in message window, press
ENTER
to
change RI mode and return “SEL.AXIS” state.
Press
AC
to cancel your selection and return “SEL.AXIS”
state.
5. Press
ENTER
to exit “RI.MODE” setup.
7.17
Enable/Disable Edge Detection
Function: SW4000 series DRO can zero Z axis display value in normal display state when an external
signal is detected if edge detection is enabled
0: Edge detection is disabled, The DRO doesn’t zero Z axis display value in normal display state
when external signal detected.
1: Edge detect is enable. The DRO zeroes Z axis display value in normal display state when an
external signal is detected.
Default value: 0 (edge detection is disable)
Example: Enable edge detection
STEPS:
1. Enter “SETUP”, then press
or
until message
window displays “AUTO.SCH”;
2. Press
ENTER
, then Y window will display the former setting;
3. Press
1
to enable edge detects;