SW4000 USER’S MANUAL
VER5.13 57
3. Input the Z axis Dial;
Press
2
.
4
in turn to input Z axis Dial;
If incorrect data has been inputted, press
AC
to cancel
and input again;
If a minus has been inputted, the DRO will accept its
absolute value instead.
4. Press
ENTER
to confirm your setting and exit Z DAIL
setup.
7.7
Setting the Resolution of Scale
Different scale has different resolution. SW4000 DRO can connect with 10 kinds of scale, and
these resolutions are 0.05µm, 0.1µm, 0.2µm, 0.5µ m, 1µm, 2µm, 5µm, 10µm, 20µm, 50µm. The
resolution must be set to match the linear scale. This parameter is set by erector, operator had better not
change it.
Default resolution: 5µm
Set the resolution of X axis, Y axis, Z axis as 1um.
STEPS:
1. Enter “SETUP” and press
or
until
“RESOLUTE” appears in message window;
2. Press
ENTER
,
X window, Y window and Z window displays the
former resolution of each axis separately. Message window
displays “SEL AXIS”, which indicates the next step is to
select axis.
3. Select axis.
Press
X
to change the resolution of X axis, then data in X
windows flashes.
Press
Y
to change the resolution of Y axis, then data in Y
windows flashes.
Press
Z
to change the resolution of Z axis, then data in Z
windows flashes.