SW4000 USER’S MANUAL
VER5.13 61
4. Press
ENTER
to confirm your change and exit “ERROR”
setup.
Press
AC
to cancel your change and exit “ERROR” setup.
7.12
Setting Shrinkage Ratio
Shrinkage ratio must be set before using shrinkage function. Shrinkage ratio must be the range of 0.1 to 10.
Default ratio: 1.000
Set the shrinkage ratio 0.975.
STEPS:
1. Enter “SETUP” and press
or
until “SHRINK”
appears in message window;
2. Press
ENTER
, then Y window displays the former
shrinkage ratio and message window displays “SHRINK”;
3. Input shrinkage ratio;
Press
0
9
7
5
in turn;
If incorrect data has been input, press
AC
to cancel and
input again.
4. Press
ENTER
to confirm your input and exit “ERROR”.
Note: shrinkage ratio =
7.13
Enable/Disable EDM Depth Compensation
In EDM machine, deep compensation is no necessary and this function disabled normally. It must be
enabled before using it.
Default setting: disable depth compensation.
STEPS:
1. Enter “SETUP” and press
or
until the message
window displays “DEEP.COMP”;
Dimensions of the finished product
Dimensions of the working piece