– One USB 3.0 internal connector on the system board for the USB hypervisor key
• Four-port integrated SATA controller
• One-port integrated SATA port for the optical drive (optional)
• One serial port header (functional with Serial Port Upgrade Kit installed)
• One video graphics array (VGA) connector on the rear
Video controller (integrated into IMM2):
• Matrox G200eR2
• SVGA compatible video controller
• AAVICA hardware video compression
• Video memory is not expandable
• Maximum video resolution: 1600 x 1200 at 75 Hz
Size:
• 1U
• Height: 43 mm (1.69 inches)
• Depth: 576 mm (22.68 inches)
• Width:
– Without Electronic Industries Association (EIA) brackets: 434.6 mm (17.11 inches)
– With EIA brackets: 482 mm (18.98 inches)
• Maximum weight: 13.8 kg (30.36 lb)
Acoustical noise emissions:
Sound power: 5.4 bels for both idle and operating environment
In the idle environment, the server is only running the operating system. In the operating environment,
the microprocessor is active and the thermal design power (TDP) is occupied 50%.
The noise emission level stated is the declared upper limit sound power level, in bels, for a random
sample of machines. All measurements are made in accordance with ISO 7779 and reported in
conformance with ISO 9296.
Environment:
• Air temperature:
– Server on: 10°C to 35°C (50.0°F to 95.0°F); altitude: 0 m to 914.4 m (0 ft to 3000 ft)
– Server on: 10°C to 32°C (50.0°F to 89.6°F); altitude: 914.4 m to 2133.6 m (3000 ft to 7000 ft)
– Server on: 10°C to 28°C (50.0°F to 83°F); altitude: 2133.6 m to 3050 m (7000 ft to 10 000 ft)
– Server off: 10°C to 43°C (50°F to 109.4°F)
– Shipping: -40°C to 60°C (-40°F to 140°F)
• Humidity: 8% to 80%
• Particulate contamination:
Airborne particulates and reactive gases acting alone or in combination with other environmental
factors such as humidity or temperature might pose a risk to the server. For information about the
limits for particulates and gases, see “Particulate contamination” on page 667.
When the operating temperature enhancement kit is installed, the temperature response for the fan
speed control is more accurate.
8
Lenovo System x3250 M6 Installation and Service Guide
Summary of Contents for x3250 m6
Page 1: ...Lenovo System x3250 M6 Installation and Service Guide Machine Types 3633 and 3943 ...
Page 6: ...iv Lenovo System x3250 M6 Installation and Service Guide ...
Page 18: ...4 Lenovo System x3250 M6 Installation and Service Guide ...
Page 60: ...46 Lenovo System x3250 M6 Installation and Service Guide ...
Page 100: ...86 Lenovo System x3250 M6 Installation and Service Guide ...
Page 516: ...502 Lenovo System x3250 M6 Installation and Service Guide ...
Page 678: ...664 Lenovo System x3250 M6 Installation and Service Guide ...
Page 685: ...Taiwan Class A compliance statement Appendix E Notices 671 ...
Page 695: ......
Page 696: ......