Attention:
• To avoid damage to the hard disk drive connectors, make sure that the server cover is in place and fully
closed whenever you install or remove a hard disk drive.
• To ensure adequate system cooling, do not operate the server for more than two minutes without either
a hard disk drive or a filler installed in each bay.
To remove a simple-swap hard disk drive, do the following:
Step 1.
Turn off the server. Then, disconnect all external cables and remove all peripheral devices.
Step 2.
Remove the security bezel. See “Removing the security bezel” on page 91.
Step 3.
Remove a simple-swap hard disk drive.
• For the 2.5-inch drive, slide the release latch
1
to the left and pull the hard disk drive out of the
drive bay at the same time.
00
0
0
Figure 32. 2.5-inch simple-swap hard disk drive removal
• For the 3.5-inch drive, remove the drive bay filler
1
from the server. Then, slide the release latch
2
to the right and pull the hard disk drive out of the drive bay at the same time.
000
000
000
000
000
000
000
000
000
000
000
000
0
0
00000000
00000000
00000000
00000000
00000000
00000000
Figure 33. 3.5-inch simple-swap hard disk drive removal
Step 4.
Depending on your needs, install a new drive and then reinstall the filler or install the filler directly.
Step 5.
Complete the parts replacement. See “Completing the parts replacement” on page 172.
104
Lenovo System x3250 M6 Installation and Service Guide
Summary of Contents for x3250 m6
Page 1: ...Lenovo System x3250 M6 Installation and Service Guide Machine Types 3633 and 3943 ...
Page 6: ...iv Lenovo System x3250 M6 Installation and Service Guide ...
Page 18: ...4 Lenovo System x3250 M6 Installation and Service Guide ...
Page 60: ...46 Lenovo System x3250 M6 Installation and Service Guide ...
Page 100: ...86 Lenovo System x3250 M6 Installation and Service Guide ...
Page 516: ...502 Lenovo System x3250 M6 Installation and Service Guide ...
Page 678: ...664 Lenovo System x3250 M6 Installation and Service Guide ...
Page 685: ...Taiwan Class A compliance statement Appendix E Notices 671 ...
Page 695: ......
Page 696: ......