2. Reseat the affected adapters and riser card.
3. Update the server firmware (UEFI and IMM) and adapter firmware. Important: Some cluster
solutions require specific code levels or coordinated code updates. If the device is part of a
cluster solution, verify that the latest level of code is supported for the cluster solution before
you update the code.
4. Replace the affected adapters.
5.
Replace the riser card.
6. (Trained service technicians only) Replace the system board.
•
806f0023-2101ffff : Watchdog Timer expired for [WatchdogElementName]. (IPMI Watchdog)
This message is for the use case when an implementation has detected a Watchdog Timer Expired.
May also be shown as 806f00232101ffff or 0x806f00232101ffff
Severity
Info
Serviceable
No
Automatically notify support
No
Alert Category
System - Other
SNMP Trap ID
CIM Information
Prefix:
PLAT
ID:
0368
User Response
No action; information only.
•
806f0107-0301ffff : An Over-Temperature Condition has been detected on [ProcessorElementName].
(CPU 1)
This message is for the use case when an implementation has detected an Over-Temperature Condition
Detected for Processor.
May also be shown as 806f01070301ffff or 0x806f01070301ffff
Severity
Error
Serviceable
Yes
Automatically notify support
No
330
Lenovo System x3250 M6 Installation and Service Guide
Summary of Contents for x3250 m6
Page 1: ...Lenovo System x3250 M6 Installation and Service Guide Machine Types 3633 and 3943 ...
Page 6: ...iv Lenovo System x3250 M6 Installation and Service Guide ...
Page 18: ...4 Lenovo System x3250 M6 Installation and Service Guide ...
Page 60: ...46 Lenovo System x3250 M6 Installation and Service Guide ...
Page 100: ...86 Lenovo System x3250 M6 Installation and Service Guide ...
Page 516: ...502 Lenovo System x3250 M6 Installation and Service Guide ...
Page 678: ...664 Lenovo System x3250 M6 Installation and Service Guide ...
Page 685: ...Taiwan Class A compliance statement Appendix E Notices 671 ...
Page 695: ......
Page 696: ......