Group 6
Operation – description of the device
Page 60
Release 3.00
Leibinger-Jet 2 se
6.5.2 Controller board
Dangerous electrical voltage!
Contact causes serious damage through an electric shock!
Disconnect the device from the mains supply prior to opening.
Remove mains plug!
The controller board contains the logic (CPU) and the power switching circuits of the
LEIBINGER-JET 2.
Figure 27
Controller board (conductor plate) LEIBINGER-JET 2
1 – Data interface RS 232 (RS 422 optional)
2 – Battery, lithium, 3.2 VDC
3 – PROM for FPGA module
4 – CPU with PROM
5 – Hydraulic processor
6 – RESET button
7 – Potentiometer for display illumination
(54-003 333 S)
(54-003 032 KA)
It is imperative that the instructions on the subject of battery changing
in the group
Equipping/maintenance
are observed!
7