Group 5
Transport/start up
Page 37
Release 3.00
Leibinger-Jet 2 se
Leibinger ordering number: see group replacement parts
With more difficult operating conditions (dust or humidity) shaft encoders with IP 66 form
of protection should be used.
Figure 9
Should alternative shaft encoders be used, the minimum impulse issued should be 3
impulses /mm in order to achieve a sufficient resolution!
5.3.4.2 Mechanic installation
With mechanic installation of the shaft encoders in all cases
attention must be paid to ensuring that the encoder is protected
from axial and radial burdening during assembly and in
continuous operation. For this a folding bellows or synthetic
material coupling is used.
If the circumstances allow the shaft encoder can also be adapted to a production line
with a frictional wheel.
Attention – risk of injury!
Your fingers could get caught between the frictional wheel and
the production line. Keep your hands outside the danger area.
Figure 10
Leibinger ordering number: see group replacement parts
Example: Shaft encoder with connection cable and plug
Pin Signal
Colour
A +5V
BN
0,5mm²
B GND
WH
0,5mm²
C free
D A BN
0,14mm²
E A GN
0,14mm²
F B GY
0,14mm²
G B PK
0,14mm²
H ZERO
RD
0,14mm²
J ZERO
BK
0,14mm²
K free
Pin assignment