Group 6
Operation – description of the device
Page 65
Release 3.00
Leibinger-Jet 2 se
The content is under pressure even if the device has been
disconnected from the mains supply!
Ink under pressure can spray out. Prior to opening disconnect the
device from the mains supply and release the pressure!
Risk of injury!
Spraying of ink into the eyes can cause blindness. Prior to the
opening of the device eye protection must be put on!
6.5.4.1 Main pump
Figure 31
Main pump
(54-002 001 S)
In the LEIBINGER-JET 2 a main pump
with geared motor is used to gnerate
the pressure.
The current operating pressure can be
read in the sub-menu
<E29>
“Hydraulics test & parameters”.
The function of the LEIBINGER-JET 2 or the creation of the ink
pressure presupposes the
functioning of the compressor
.
6.5.4.2 Suction pump
Figure 32
Suction pump
(54-002 002 S)
The suction pump is a membrane
pump and is used for sucking up the
ink from the gutter.
The underpressure of the suction
pump is
≥
0.3 bar.