Group 5
Transport/start up
Page 34
Release 3.00
Leibinger-Jet 2 se
5.3.2 Data interface X2
The operation of the LEIBINGER-JET 2 is normally done via the LCD touch display. The
RS 232 input on the rear side of the device (9-pole plug, female, interface X2) can be
used as an external data interface for connection to a PC, notebook or host. The
standard baud rate is 38400 Baud.
For older software versions the baud rate can be reduced to 9600 baud with the help of
a special bridge plug. Further more a special plug to increase the transmission rate to
115200 is obtainable on request.
The interface enables the downloading/running of software, of jobs and of graphic
symbols. A special connection cable and the Leibinger LJ-FLASH program is required to
use this function.
Further more this interface can be used via a PC for a comfortable programming of one
or more Leibinger-Jet 2. For this you would need additionally the Leibinger-software Win
Jet.
When using a personal computer with RS 232 C interface a
maximum connection cable length of 10 metres should not be
exceeded, with greater transmission distances the use of an RS
422 connection is recommended.
5.3.2.1 Transmission protocol for operating system LJOS
The programming device that is connected to the LEIBINGER-JET 2 must work with the
following transmission protocol:
!
Asynchronous Mode
!
8 bit/character
!
1 stop bit
!
Parity = no parity, no parity calculation
Figure 6