Group 9
Equipping/maintenance
Page 135
Release 3.00
Leibinger-Jet 2 se
!
Cleaning of the nozzle only with LEIBINGER solvent against and in the direction of
the current or with the help of an ultrasound bath and subsequent blowing out with
compressed air. Further information on this subject area can be found in the chapter
Cleaning
.
!
Installation of the cleaned or new nozzle plate.
!
The bar that fixes the nozzle plate must be swivelled downwards so that the nozzle
plate is fixed centrally.
!
The knurled screw can be tightened as far as the stop (by hand only, without tools).
!
The ink can be switched on with the ink switch (switch upwards). When so doing,
attention should be paid to the fact that in the event of incorrect installation ink can
spray out.
Observe safety instructions!
!
If the ink jet enters the gutter, the correct position of the jet in the gutter must be
checked and if necessary a fine adjustment must be done with the adjusting screws.
Insufficient or incorrect cleaning leads to jet jumping with repeated switching on and
off of the ink switch. Only if the cleaning has been carried out correctly will the ink jet
always enter the gutter at the same point. Further information on the adjustment of
the ink jet can be found in the chapter
Other servicing work
.
!
Following the check of the above mentioned points the gutter can be closed and the
deflector unit swivelled downwards carefully by release of the toggle lever.
!
Prior to starting the print operation the print head should be checked once again and
possibly cleaned. Further information on this subject area can be found in the
chapter
Cleaning
. Following an extended idle period it is expedient to switch the
device on and off again in order to trigger a bleeding procedure.
9.3.3 Annual servicing work
The manufacturer recommends a regular servicing interval of 6–12 months. Integral
parts of this servicing are:
!
Replacement of filter elements and ink
!
Replacement of the O-rings for filter and nozzle seal