Group 6
Operation – procedures and elements
Page 47
Release 3.00
Leibinger-Jet 2 se
6.3 Operating procedures and operating
elements
6.3.1 LCD touch display
6.3.1.1 Switching on/switching off procedure
Figure 14
The LEIBINGER-JET 2 is switched on by
touching any point of the touch display (1)
that is still dark. Contact duration approx. 2
sec.
The start screen with the software-version
number (2) and the execution identification
(3) are displayed for 3 sec..
Information about execution
identification:
64 = Actual frequency 64 KHz
96 = Actual frequency 96 KHz
n = for non-pigmented ink
p = for pigmented ink
The entire control is performed via the
touching of the touch fields. The fields are
activated by light touching with the finger or
the touch pen (included in the scope of
delivery) whereby the precision and not the
pressure is decisive.
Only fields with
bold
frames are active and
operable. Thinly edged fields (buttons) are
currently not operable.
Now the device starts automatically with
the bleeding of the system. The bleeding
lasts between 1-5 minutes. During the
procedure the notification
“BLEED”
flashes in the
status line
(4). The bleeding
procedure is ended by pressing
the
status line
. Following ending or after cancelation of the bleeding the
status display
(3) of the device alters
(see following figure)
.
2
3
4
[E0]