Group 9
Equipping/maintenance
Page 142
Release 3.00
Leibinger-Jet 2 se
9.3.4.3 Replacement of the battery and fuse
Dangerous electrical voltage!
Contact causes serious damage through an electric shock!
Disconnect the device from the mains supply prior to opening.
Remove mains plug!
Dangerous electrical voltage!
Parts of the device are still under voltage after blowing the
protecting device! Disconnect the device from the mains supply
prior to opening
.
Remove mains plug!
Caution – risk of explosion!
Risk of explosion in the event of incorrect replacement of the
battery. Replace only with an identical battery or with an equal
value battery type in accordance with the recommendations of the
manufacturer! The instructions of the battery manufacturer must
be observed when disposing of the battery!
Replacement of the battery!
This work must only be carried out by trained personnel or by
Leibinger service technicians!
The battery and the fuse are situated in the electronics housing on the controller board
or on the mains part. If necessary the fuse and the battery must be replaced. When
changing the battery it is imperative that the
Safety instructions
as well as the
Disposal instructions
of the battery manufacturer are observed!
Figure 109
1 – Battery,
lithium, 3.2 VDC
(54-003 032 KA)
2 – Fuse 1,6 H
(54-003 339 KA)
1
2