Release 3.00
Leibinger-Jet 2 se
7.7.6.6 Hydraulic test & parameters
This work must only be carried out by trained personnel or by
Leibinger service technicians!
Figure 99
The touch field
<hydrauic test &
parameter>
(190) activates the hydraulic
menu
<E29>
.
If the regulation
not inverted
is shown, i.e.
is switched off, each individual component
can be driven individually.
Storage of the values is only possible in the
<service >
area (191).
(for further information see the following
page)
With the touch field
<bleed>
(192) the device can be bleeded. The bleeding is only
carried out as long as the button is active.
With the touch field
<pressureless>
(195) the device can be set in a pressureless
operating mode. The function is only available for a deactivated control!
The touch field
<falltime>
(193) starts a new measurement of the current fall time. After
approx. 15 seconds the value is updated. The issue of the value is made in milliseconds.
In the
<display zone>
(194) the current system pressure in mbar, the current position of
the membrane as well as the mix information (values on the addition of ink and solvent)
are shown.
Before exiting with <ESCAPE> it is imperative that the regulation
again be switched on.
Incorrect operation can lead to major disturbances to the device!