Group 6
Operation – description of the device
Page 63
Release 3.00
Leibinger-Jet 2 se
6.5.4 Hydraulics part
The content is under pressure even if the device has been
disconnected from the mains supply!
Ink under pressure can spray out. Prior to opening disconnect the
device from the mains supply and let off the pressure!
Risk of injury!
Spraying of ink into the eyes can cause blindness. Prior to the
opening of the device eye protection must be put on!
All components that are necessary for the conveying and preparation of the ink are
accommodated in the
Hydraulics part
. This is situated in the rear section of the device.
Figure 29
1 – Rear wall fastening
screws
2 – Rear wall
The hydraulic parts are made accessible for service purposes through opening of the
fastening screws and removal of the rear wall (see illustration).
This work must only be carried out by trained personnel or by
Leibinger service technicians!
1
2