Group 7
Data Entry
Page 122
Release 3.00
Leibinger-Jet 2 se
This work must only be carried out by trained personnel or by
Leibinger service technicians!
Figure 100
The touch field
<nom. visko>
(196)
serves the entry of the target fall time
in milliseconds, the para-meters are
ink and device specific.
The touch field
<nom. pressure>
(197) the print values can be
changed. The entry is in mbar.
The touch field
<suct.>
(198) alters the settings of the suction pump. The standard
values are “144” for devices without head ventilation and “240” for devices with head
ventilation.
Observation:
The value must be entered in four digit form (e.g.: “0240”).
The
field
<viskor>
(199) is required for the entry of the viscosity metre correction value.
The entry is necessary following the replacement of the viscosity metre pipe. The value
engraved on the Viskosity meter must be entered here. Viscosity meters without a
engraving have the Value 1000. See group
Equipping/maintenance
.
Language change-over
In
the
field
(200) the menu language of the device is displayed! The alternative menu
language of the device is displayed in the
field
(201). If required you can change to
another alternative menu language online (e.g. in case of service) to simplify the
communication with the dealer or the LEIBINGER Service – Hotline. The change
happens by pressing the touch field
<english>
(201). You can go back to the standard-
menu language with the touch field (200).
Observation:
If the device will be switched off after a change of the menu language
the standard-menu language will be loaded automatically if you switch
on the high-speed printer again!
Alterations to the parameters already pre-set can lead to serious
functional disturbances!
[E43]
198
199
196
200
201
202
197