Group 9
Equipping/maintenance
Page 149
Release 3.00
Leibinger-Jet 2 se
Checking of the jet cleaning carried out
With repeated switching of the ink flow valve (by pressing of the ink on/off switch) the ink
jet must always assume the same position. If this is not the case, renewed cleaning is
necessary.
9.4.3.2 Cleaning the suction pump
The content is under pressure even if the device has been
disconnected from the mains supply!
Ink under pressure can spray out. Prior to opening disconnect the
device from the mains supply and let off the pressure!
Risk of injury!
Spraying of ink into the eyes can cause blindness. Prior to the
opening of the device eye protection must be put on!
Risk of injury!
Upon contact the contents causes skin irritation. Protective
equipment is necessary!
This work must only be carried out by trained personnel or by
Leibinger service technicians!
Figure 113
Suction pump
(54-002 002 S)
The suction pump works with an
underpressure > 0.3 bar. If this is not
achieved, dirtying of the valve reeds or
damage to the working membrane can
be present.