To be done before spreading
96
Review and adaptation
The maximum acceptable loss in the ditch is determined by
environment standards (EN 13739-1). In order to comply with the
standards the quantity of fertilizer in the 1st trough, standing in the
imaginative ditch, must be a maximum of 10% of the quantity collected
in the trough in the middle of the track (= 100%).
The trough on the land next to the fictive ditch provides an insight into
the topping. It will never be 100%.
If you adjust the ExactLine 1 setting higher or lower (e.g. from 1 to 2,
or from 3 to 2), the working width on the side of the ditch changes
roughly as follows:
•
Spreader horizontally: 0.98 ft,
•
Spreader 8º headlong: 1.64 ft.
Setting the spreading height back to the tray test
During the tray test the disc height above the troughs was set to 75
cm/29.5 in.
Imagine spreading with the disc height at 75 cm/29.5 in above the
ground or crops!
See paragraph »Spreading height« on page 100.
A
Good spreading pattern, the ExactLine has been adjusted
well.
B
The ExactLine is not spreading wide enough.
Adjust this 1 setting wider (e.g. from 3 to 4 or from 9 to
transport setting)
Repeat the test
C
The ExactLine is spreading too wide.
Adjust this 1 setting narrower (e.g. from 5 to 4 or from
transport setting to 9)
Repeat the test
A
Ditch side
B
C