Troubleshooting
160
Troubleshooting
Troubleshooting table
Problem
Possible cause
Solution
Pag
e
Incorrect appli-
cation rates
(kg per hec-
tare)
Dosing setting incorrectly set
Check the dosing setting
80
Incorrect setting for fine dosage
Set the dosing setting for fine application
as per the instructions
69
Driving speed signal not correctly set
Set the correct source of the driving speed
signal in the control system, as well as the
control box
Incorrect driving speed signal
Calibrate the driving speed
Incorrect distance between the driving
tracks
Always set the driving tracks before
spreading
102
New type of fertiliser spread with the
same settings as the previous type.
Quality varies greatly between types.
Determine the characteristics of the fertil-
iser, look for the relevant spreading chart
and set the spreader again
59,
64
The flow of the fertiliser is blocked
Clean the machine well after each use.
Replace the agitator if it is worn out
124
Dosing setting and flowrate not entered
on the ‘Spreading Settings 1’ screen be-
fore work is started
Find the correct values in the spreading
chart and enter them
68
Incorrect application rate, working width
and/or letter value discharge point en-
tered
Enter the correct values in the control sys-
tem
64
The control system is being operated
manually, so it does not perform automat-
ic calibration
Switch to automatic operation
Incorrect values entered after a manual
calibration test at a manually entered ap-
plication rate
Perform the calibration test in the correct
manner and enter the result obtained
73
The speedometer is incorrect or not
measuring
Check the sensors and cables and cali-
brate the wheel sensor or radar
41
For a tractor without driving speed meas-
urement: the simulated and real driving
speeds do not correspond
Adjust the simulated driving speed on the
main screen or the real driving speed
41
Difference be-
tween the flow-
rate on the left
and the right
spreading
discs
Actuators set unequally
Check the settings
141,
144
The stop of one or both of the actuators
have been moved
Check the position of the connecting
points and readjust them
141
Discharge is blocked on the one side
Clean the machine well after each use.
Replace the agitator if it is worn out
124