Troubleshooting
161
Great amounts
of dust while
spreading
Average quality fertiliser (too soft, broken,
mixed types) or incorrect storage
Contact your supplier.
Update the storage area.
Spread with smaller working widths as far
as possible
59,
61,
66
Rpm on the spreading discs too high
Check the PTO shaft speed and the cou-
pling shaft mounting point
47,
67
agitator grinds. Dosing units closed for too
long with the PTO shaft running
Switch the PTO shaft off after closing the
dosing units.
Check the agitator for damage
Right agitator grinds
Spreading disc not disconnected while
border spreading with the border spread-
ing plate
111
Spreading
tracks visible
among the
crops
Average quality fertiliser. 80% of the gran-
ules with a diameter between 2.0 - 4.75
mm
Determine the distribution and spread
with small working widths if possible
61,
66
Blend of fertiliser types used. A blend can
become unmixed again or types of fertil-
iser could contain varying spreading qual-
ities
Check the type, pattern and distribution.
Spread with smaller working widths as far
as possible
59,
61
New type of fertiliser spread with the
same settings as the previous type.
Quality varies greatly between types.
Determine the characteristics of the fertil-
iser, look for the relevant spreading chart
and set the spreader again
59,
64
Use of wrong spreading chart
Determine the characteristics of the fertil-
iser and select the correct spreading chart
59,
62
Working with unfavourable weather con-
ditions: high levels of humidity, rain, heat
or high wind speeds (> 5 m/sec)
Only work under good weather conditions
Incorrect overlapping of the spreading
pattern
Always set the driving tracks before
spreading
102
Horizontal/vertical settings of the machine
not correct
Check if the machine is standing level
horizontally and vertically, unless the
spreading chart indicates otherwise
55, ,
99
Spreader not set to the correct height
Check and set to the correct working
height (75 cm above the crops or soil) and
inclination
99
Working width incorrect
Check the discharge point letter and the
PTO shaft RPM
67,
67
Worn or missing vanes
Check the vanes
66
Tyre pressure on the left and right not the
same
Check the tyre pressure
The setting mechanism of the discharge
point is not set well
Perform the »Checking and setting the
discharge point setting mechanism«
144
The dosing mechanism is not set well
Perform the »Checking and setting the
dosing mechanism«
144
Problem
Possible cause
Solution