Maintenance
149
Open the sieves and lock them.
Remove the agitator from the agitator axle.
Support the fertilizer bearing ring through a dosing opening so that
it will not drop.
Remove the 3 fastening bolts from the seal rings.
Remove the metal seal rings.
Check the condition of the agitator axle.
Replace the fertilizer sealing ring.
Put the metal seal rings back in position.
Put the 3 fastening bolts back in place.
T
IP
You can let go of the bearing ring after the first fastening bolt has been
put back in place.
Put the agitator back into the agitator axle.
Check the connections as described in
paragraph »Checking and setting the dosing mechanism« on page
141.
agitator axle
Seal ring
agitator axle
Bolt holes
Plastic sealer rings
agitator
agitator axle