To be done before spreading
92
Review and adaptation
The maximum acceptable loss in the ditch is determined by
environment standards (EN 13739-1). In order to comply with the
standards the quantity of fertilizer in the 1st trough, standing in the
imaginative ditch, must be a maximum of 10% of the quantity collected
in the trough in the middle of the track (= 100%).
The trough on the land next to the fictive ditch provides an insight into
the topping. It will never be 100%.
Test the full field spreading pattern next as described in the
following paragraph.
A
Good spreading pattern, the border spreading plate has
been adjusted well.
B
The border spreading plate is not spreading wide enough.
Set this a bit to the right in the direction of Y(9) (= ditch).
Repeat the test.
C
The border spreading plate is spreading too wide.
Set this a bit to the left in the direction of X (1) ( = field).
Repeat the test.
A
Ditch side
B
C
X
Y
Border spreading plate, position for a working
width of 33 - 59 ft
1
9
Hydraulic border spreading plate