To be done before spreading
82
Assessment
Record the values you find in the graduated tubes for the left and
right spreading discs.
Compare the values, calculate the percentage differences
between the measuring tubes on the left and the right.
Adaptation
If the spreading patterns on the left and right spreading discs are not
the same and the difference is greater than 3% you will have to do the
following, or request your dealer to do so:
Check if the machine is hanging horizontally and vertically behind
the tractor in length and width.
Perform the »Checking and setting the dosing mechanism« as
described on page 141 and repeat the test.
Perform the »Checking and setting the discharge point setting
mechanism« as described on page 144 and repeat the test.
If the difference in the spreading pattern is too great, contact your
dealer.