346
KHA3000
Default Conditions
When *RST or MEAS? is sent or the power is turned on, parameters are set as shown in
table below.
See
Command
Parameter value
Unit
Function
*RST
MEAS?
*1
Power-on
INP:LINK
1(ON)
Same
–
Setting
immediately
before the
POWER
switch is
turned off
–
Sets the input circuit of each
input phase (channel) to the
same value or sets it
independently.
INP:WIR:METH
“
3P4
W”
–
–
Wiring method
INP:PLL:SOUR
VL1
–
–
PLL input phase
INP:COUP
DC
DC
A
Input coupling
INP:FILT:FREQ
6000
6000
Hz
Cutoff frequency of anti-
aliasing filter
INP:CURR:TERM
SHUNt
(all
channels)
–
–
Current input terminal (phases
linked)
INP:CURR:TERM:IND
SHUNt
–
–
Current input terminal (phases
independent)
FUNC
“HARM”
–
–
Operation mode
CURR:RANG
CURR:RANG:IND
Selected
value for the
auto range
Selected
value for the
auto range
A
Current range (phases linked
or independent)
CURR:RANG:AUTO
CURR:RANG:AUTO:IND
1(ON)
1(ON)
–
Enable or disable Auto Range
of current range
VOLT:RANG
VOLT:RANG:IND
Selected
value for the
auto range
Selected
value for the
auto range
V
Voltage range (phases linked,
phases independent)
VOLT:RANG:AUTO
VOLT:RANG:AUTO:IND
1(ON)
1(ON)
–
Enables/Disables the auto
range for the voltage range
CURR:SCAL
0(OFF)
–
–
Enable/disable current scaling
CURR:SCAL:CF
4.00
–
–
Current CF
CURR:SCAL:CTR
1.000
–
–
CT Ratio
CURR:SCAL:ESCR
25.000
–
–
EXT-CS
CURR:SCAL:PADJ
0.00
–
–
Phase adjustment value for
the external current sensor
VOLT:SCAL
0(OFF)
–
–
Enable/disable voltage scaling
VOLT:SCAL:CF
2.00
–
–
Voltage CF
VOLT:SCAL:PTR
1.000
–
–
PT Ratio
HARM:STAN:LIM:NAME
“IEC
61000-
3-2Ed5.0
”
No change
–
Harmonic current limit value
standard
HARM:STAN:MTEC:NAME
“IEC
61000-
4-7Ed2.0A1
”
No change
–
Harmonic current measuring
technique standard
HARM:STAN:LIM:ALI
0(OFF)
–
–
Specifies the naming of
Standard
HARM:STAN:LIM:ALI:NAME
Standard
name
–
–
Limitation standard name
HARM:STAN:MTEC:ALI:NAME Standard
name
–
–
Measuring technique name
HARM:NOM:FREQ
50
–
Hz
Nominal frequency
HARM:NOM:VOLT
230
–
V
Nominal voltage
HARM:MARG
100
–
%
Margin
HARM:MTIM
150
–
s
Measurement time
Summary of Contents for KHA3000
Page 20: ...20 KHA3000...
Page 42: ...42 KHA3000 Options...
Page 70: ...70 KHA3000 Connecting Communication Cables...
Page 71: ...System Setup This chapter explains how to turn on the power and how to set up the system 4...
Page 120: ...120 KHA3000 Controlling the AC Power Supply...
Page 182: ...182 KHA3000 Checking the AC Power Supply and Repeatability...
Page 349: ...Maintenance This chapter explains how to clean and inspect this product 14...
Page 352: ...352 KHA3000 Cleaning and Checking...
Page 353: ...Specifications This chapter explains the specifications of this product 15...
Page 390: ...390 KHA3000...
Page 391: ......