Starting the Test by Pressing the START Key
(61000-3-3)
In IEC 61000-3-3 standard, different test procedures are used depending on the selection of
Limitation Standard.
•
When 61000-3-3 (Pst Auto) is selected, the test duration of
“
Pst Meas Time
”
is
continuously repeated for the number of times defined by
“
Pst Meas Count
”
and the test
is terminated upon completion of the
“
Pst Meas Count
”
.
•
When 61000-3-3 (Manual SW) is selected, the measurement is stopped each time the
“
d Meas Time
”
of one
“
d Meas Count
”
cycle is completed. During the pause, prepare the
EUT for the next operation and then command this product to start the test for the next
“
d
Meas Time
”
. After repeating this procedure, terminate the test when the cycles defined
by
“
d Meas Count
”
are completed.
The currently selected Limitation Standard can be checked by the Standard name shown in
the display.
1
Press the VIEW key.
The Vf-Observation and Analysis display appears.
2
Select a view type for the test.
To observe voltage fluctuations, select Pinst (St) Waveform. Some displays can be
selected only after the test ends.
3
Press the START key.
The dialog box for confirming the line impedance is displayed.
If the optional current sensor is not connected or recognized although "Sensor" is
selected in the Current Input Terminal setting, a confirmation dialog will be presented.
If the sum (
) of the real power of each input phase is negative, a confirmation dialog
will be presented.
4
Select the F1 key (OK), after checking the setting of the test conditions
according to the comment in the dialogbox.
If the F2 key (Cancel) is selected, the test start is canceled. To start the test, return to
Step 3.
The test is started.
See
Limitation Standard Name
See
See
Display during test
Test status display
Switches from
“
Set
”
to
“
Test.
”
The progress bar extends from left to right. When it reaches the right
end, the test ends.
Time display
Remaining test time
View type
The view type that is set in the Vf-Observation and Analysis display
(Vf-VIEW)
Summary of Contents for KHA3000
Page 20: ...20 KHA3000...
Page 42: ...42 KHA3000 Options...
Page 70: ...70 KHA3000 Connecting Communication Cables...
Page 71: ...System Setup This chapter explains how to turn on the power and how to set up the system 4...
Page 120: ...120 KHA3000 Controlling the AC Power Supply...
Page 182: ...182 KHA3000 Checking the AC Power Supply and Repeatability...
Page 349: ...Maintenance This chapter explains how to clean and inspect this product 14...
Page 352: ...352 KHA3000 Cleaning and Checking...
Page 353: ...Specifications This chapter explains the specifications of this product 15...
Page 390: ...390 KHA3000...
Page 391: ......