100
KHA3000
61000-3-2
3rd/5th/Current Wave
(
Limit Values
)
If you set Limit Values to “3rd/5th/Current Wave,” the tests using third and fifth harmonic currents
and current waveforms that are shown in section 7.4.
3, “Rated power
5 W and
25
W” of IEC
61000-3-2 Ed5.0 are performed. (It is only valid for single-phase, two-wire circuits.)
When you select “3rd/5th/Current Wave,” the phase angles of the points of the current
waveform are displayed on the V/I waveform screen. This is only valid when the view area is
set to 1-Screen.
The phase angles of the points of the current waveform are measured automatically. From the
cycle that includes the maximum absolute peak value within the window, the phase angles
are determined from the following references: the points that reached the current threshold
(which is 5 % of the absolute peak) and the points where the voltage crossed zero on the
rising and falling slopes.
Correct judgments cannot be made for half-wave rectification circuits.
Ipk(abs): Maximum absolute
peak value within the
window
0.05*Ipk: Current threshold
P1, P4: The phase angles of the
points where the curr-
ent reached the current
threshold with the
points where current
began flowing as the
references
P2, P5: Phase angles of the
positive and negative
peaks
P3, P6: The phase angles of the
points where the curr-
ent decreases to the
threshold
Summary of Contents for KHA3000
Page 20: ...20 KHA3000...
Page 42: ...42 KHA3000 Options...
Page 70: ...70 KHA3000 Connecting Communication Cables...
Page 71: ...System Setup This chapter explains how to turn on the power and how to set up the system 4...
Page 120: ...120 KHA3000 Controlling the AC Power Supply...
Page 182: ...182 KHA3000 Checking the AC Power Supply and Repeatability...
Page 349: ...Maintenance This chapter explains how to clean and inspect this product 14...
Page 352: ...352 KHA3000 Cleaning and Checking...
Page 353: ...Specifications This chapter explains the specifications of this product 15...
Page 390: ...390 KHA3000...
Page 391: ......