CSV and ASCII XY file structure
In CSV or ASCII XY format the
Length
control selects the number of points per
segment. All segments are contained in the CSV file or in each ASCII XY data file.
For example: If the Length control is set to 1000 points, there will be 1000 points
(rows in the spreadsheet) per segment. When saving all segments there are three
header rows, so the data for the first segment starts at row 4. The second
segment's data starts at row 1004. The time column shows the time since the
trigger on the first segment. The top row shows the selected number of points per
segment.
BIN files are a more efficient data transfer format than CSV or ASCII XY. Use this
file format for fastest data transfer.
Minimum and Maximum Values in CSV Files
If you are running a Minimum or Maximum measurement, the minimum and
maximum values shown in the measurement display may not appear in the CSV
file.
Explanation:
When the oscilloscope's sample rate is 4 GSa/s, a sample will be taken every
250 ps. If the horizontal scale is set to 10 us/div, there will be 100 us of data
displayed (because there are ten divisions across the screen). To find the total
number of samples the oscilloscope will take:
100 us x 4 GSa/s = 400K samples
The oscilloscope is required to display those 400K samples using 640 pixel
columns. The oscilloscope will decimate the 400K samples to 640 pixel columns,
and this decimation keeps track of the min and max values of all the points that
are represented by any given column. Those min and max values will be displayed
in that screen column.
A similar process is used to reduce the acquired data to produce a record usable
for various analysis needs such as measurements and CSV data. This analysis
record (or
measurement record
) is much larger than 640 and may in fact contain
up to 65536 points. Still, once the # of acquired points > 65536, some form of
decimation is required. The decimator used to produce a CSV record is configured
to provide a best-estimate of all the samples that each point in the record
represents. Therefore, the min and max values may not appear in the CSV file.
Summary of Contents for DSO-X 2014A
Page 1: ...Keysight InfiniiVision 2000 X Series Oscilloscopes User s Guide...
Page 8: ...8 Keysight InfiniiVision 2000 X Series Oscilloscopes User s Guide...
Page 60: ...60 Keysight InfiniiVision 2000 X Series Oscilloscopes User s Guide 2 Horizontal Controls...
Page 68: ...68 Keysight InfiniiVision 2000 X Series Oscilloscopes User s Guide 3 Vertical Controls...
Page 118: ...118 Keysight InfiniiVision 2000 X Series Oscilloscopes User s Guide 6 Digital Channels...
Page 124: ...124 Keysight InfiniiVision 2000 X Series Oscilloscopes User s Guide 7 Serial Decode...
Page 130: ...130 Keysight InfiniiVision 2000 X Series Oscilloscopes User s Guide 8 Display Settings...
Page 168: ...168 Keysight InfiniiVision 2000 X Series Oscilloscopes User s Guide 10 Triggers...
Page 176: ...176 Keysight InfiniiVision 2000 X Series Oscilloscopes User s Guide 11 Trigger Mode Coupling...
Page 202: ...202 Keysight InfiniiVision 2000 X Series Oscilloscopes User s Guide 13 Cursors...
Page 226: ...226 Keysight InfiniiVision 2000 X Series Oscilloscopes User s Guide 14 Measurements...
Page 240: ...240 Keysight InfiniiVision 2000 X Series Oscilloscopes User s Guide 15 Mask Testing...
Page 244: ...244 Keysight InfiniiVision 2000 X Series Oscilloscopes User s Guide 16 Digital Voltmeter...
Page 256: ...256 Keysight InfiniiVision 2000 X Series Oscilloscopes User s Guide 17 Waveform Generator...
Page 274: ...274 Keysight InfiniiVision 2000 X Series Oscilloscopes User s Guide 19 Print Screens...
Page 308: ...308 Keysight InfiniiVision 2000 X Series Oscilloscopes User s Guide 21 Web Interface...
Page 326: ...326 Keysight InfiniiVision 2000 X Series Oscilloscopes User s Guide 22 Reference...