148
Keysight InfiniiVision 2000 X-Series Oscilloscopes User's Guide
10
Triggers
Hex Bus Pattern Trigger
You can specify a bus value on which to trigger. To do this, first define the bus. See
"To display digital channels as a bus"
on page 110 for details. You can trigger on
a bus value whether you are displaying the bus or not.
To trigger on a bus value:
1
Press the
[Pattern]
key on the front panel.
2
Press the
Channel
softkey and rotate the Entry knob to select
Bus1
or
Bus2
.
3
Press the
Digit
softkey and rotate the Entry knob to select a digit of the selected
bus.
4
Press the
Hex
softkey and rotate the Entry knob to select a value for the digit.
5
You can use the
Set all Digits
softkey to set all digits to a particular value.
When a hex bus digit contains one or more don't care (X) bits and one or more bit
with a value or 0 or 1, the "$" sign will be displayed for the digit.
For information regarding digital bus display when Pattern triggering see
values are displayed when using Pattern trigger"
OR Trigger
The OR trigger mode triggers when any one (or more) of the specified edges on
analog or digital channels is found.
1
On the front panel, in the Trigger section, press the
[Trigger]
key.
2
In the Trigger Menu, press the
Trigger
softkey, and use the Entry knob to select
OR
.
3
Press the
Slope
softkey and select rising edge, falling edge, either edge, or don't
care. The selected slope is displayed in the upper-right corner of the display.
4
For each analog or digital channel you want to include in the OR trigger, press
the
Channel
softkey to select the channel.
NOTE
If a digit is made up of less than four bits, then the value of the digit will be limited to the
value that can be created by the selected bits.
Summary of Contents for DSO-X 2014A
Page 1: ...Keysight InfiniiVision 2000 X Series Oscilloscopes User s Guide...
Page 8: ...8 Keysight InfiniiVision 2000 X Series Oscilloscopes User s Guide...
Page 60: ...60 Keysight InfiniiVision 2000 X Series Oscilloscopes User s Guide 2 Horizontal Controls...
Page 68: ...68 Keysight InfiniiVision 2000 X Series Oscilloscopes User s Guide 3 Vertical Controls...
Page 118: ...118 Keysight InfiniiVision 2000 X Series Oscilloscopes User s Guide 6 Digital Channels...
Page 124: ...124 Keysight InfiniiVision 2000 X Series Oscilloscopes User s Guide 7 Serial Decode...
Page 130: ...130 Keysight InfiniiVision 2000 X Series Oscilloscopes User s Guide 8 Display Settings...
Page 168: ...168 Keysight InfiniiVision 2000 X Series Oscilloscopes User s Guide 10 Triggers...
Page 176: ...176 Keysight InfiniiVision 2000 X Series Oscilloscopes User s Guide 11 Trigger Mode Coupling...
Page 202: ...202 Keysight InfiniiVision 2000 X Series Oscilloscopes User s Guide 13 Cursors...
Page 226: ...226 Keysight InfiniiVision 2000 X Series Oscilloscopes User s Guide 14 Measurements...
Page 240: ...240 Keysight InfiniiVision 2000 X Series Oscilloscopes User s Guide 15 Mask Testing...
Page 244: ...244 Keysight InfiniiVision 2000 X Series Oscilloscopes User s Guide 16 Digital Voltmeter...
Page 256: ...256 Keysight InfiniiVision 2000 X Series Oscilloscopes User s Guide 17 Waveform Generator...
Page 274: ...274 Keysight InfiniiVision 2000 X Series Oscilloscopes User s Guide 19 Print Screens...
Page 308: ...308 Keysight InfiniiVision 2000 X Series Oscilloscopes User s Guide 21 Web Interface...
Page 326: ...326 Keysight InfiniiVision 2000 X Series Oscilloscopes User s Guide 22 Reference...