128
Keysight InfiniiVision 2000 X-Series Oscilloscopes User's Guide
8
Display Settings
3
To erase the results of previous acquisitions from the display, press the
Clear
Persistence
softkey.
The oscilloscope will start to accumulate acquisitions again.
4
To return the oscilloscope to the normal display mode, turn off persistence;
then, press the
Clear Persistence
softkey.
Turning off persistence does not clear the display. The display is cleared if you
press the
Clear Display
softkey or if you press the
[AutoScale]
key (which also
turns off persistence).
For another method of seeing worst-case extremes of varying waveforms, see
"Glitch or Narrow Pulse Capture"
To clear the display
1
Press
[Display] > Clear Display
.
You can also configure the
[Quick Action]
key to clear the display. See
To select the grid type
When the
Video
on page 155), and the
vertical scaling of at least one displayed channel is 140 mV/div, the
Grid
softkey
lets you select from these grid types:
•
Full
— the normal oscilloscope grid.
•
mV
— shows vertical grids, labeled on the left, from -0.3 V to 0.8 V.
•
IRE
— (Institute of Radio Engineers) shows vertical grids in IRE units, labeled on
the left, from -40 to 100 IRE. The 0.35 V and 0.7 V levels from the
mV
grid are
also shown and labeled at the right. When the
IRE
grid is selected, cursor values
are also shown in IRE units. (Cursor values via the remote interface are not in
IRE units.)
The
mV
and
IRE
grid values are accurate (and match Y cursor values) when the
vertical scaling is 140 mV/division and the vertical offset is 245 mV.
To select the grid type:
Summary of Contents for DSO-X 2014A
Page 1: ...Keysight InfiniiVision 2000 X Series Oscilloscopes User s Guide...
Page 8: ...8 Keysight InfiniiVision 2000 X Series Oscilloscopes User s Guide...
Page 60: ...60 Keysight InfiniiVision 2000 X Series Oscilloscopes User s Guide 2 Horizontal Controls...
Page 68: ...68 Keysight InfiniiVision 2000 X Series Oscilloscopes User s Guide 3 Vertical Controls...
Page 118: ...118 Keysight InfiniiVision 2000 X Series Oscilloscopes User s Guide 6 Digital Channels...
Page 124: ...124 Keysight InfiniiVision 2000 X Series Oscilloscopes User s Guide 7 Serial Decode...
Page 130: ...130 Keysight InfiniiVision 2000 X Series Oscilloscopes User s Guide 8 Display Settings...
Page 168: ...168 Keysight InfiniiVision 2000 X Series Oscilloscopes User s Guide 10 Triggers...
Page 176: ...176 Keysight InfiniiVision 2000 X Series Oscilloscopes User s Guide 11 Trigger Mode Coupling...
Page 202: ...202 Keysight InfiniiVision 2000 X Series Oscilloscopes User s Guide 13 Cursors...
Page 226: ...226 Keysight InfiniiVision 2000 X Series Oscilloscopes User s Guide 14 Measurements...
Page 240: ...240 Keysight InfiniiVision 2000 X Series Oscilloscopes User s Guide 15 Mask Testing...
Page 244: ...244 Keysight InfiniiVision 2000 X Series Oscilloscopes User s Guide 16 Digital Voltmeter...
Page 256: ...256 Keysight InfiniiVision 2000 X Series Oscilloscopes User s Guide 17 Waveform Generator...
Page 274: ...274 Keysight InfiniiVision 2000 X Series Oscilloscopes User s Guide 19 Print Screens...
Page 308: ...308 Keysight InfiniiVision 2000 X Series Oscilloscopes User s Guide 21 Web Interface...
Page 326: ...326 Keysight InfiniiVision 2000 X Series Oscilloscopes User s Guide 22 Reference...