336
Keysight InfiniiVision 2000 X-Series Oscilloscopes User's Guide
23
CAN/LIN Triggering and Serial Decode
3
Press the
Mode
softkey; then, select
LIN
trigger type.
4
Press the
Signals
softkey to open the LIN Signals Menu.
5
Press the
Source
softkey to select the channel connected to the LIN signal line.
The label for the LIN source channel is automatically set.
6
Press the
Threshold
softkey; then, turn the Entry knob to set the LIN signal
threshold voltage level to the middle of the LIN signal.
The threshold voltage level is used in decoding, and it will become the trigger
level when the trigger type is set to the selected serial decode slot.
7
Press the
Baud Rate
softkey to open the LIN Baud Rate Menu.
8
Press the
Baud
softkey; then, turn the Entry knob to select the baud rate that
matches match your LIN bus signal.
The default baud rate is 19.2 kb/s.
If none of the pre-defined selections match your LIN bus signal, select
User
Defined
; then, press the
User Baud
softkey and turn the Entry knob to enter the
baud rate.
You can set the LIN baud rate from 2.4 kb/s to 625 kb/s in increments of
100 b/s.
9
Press the
Back/Up key to return to the LIN Signals Menu.
10
Press the
Sample Point
softkey; then, turn the Entry knob to select the sample
point at which the oscilloscope will sample the bit value.
11
Press the
Standard
softkey; then, turn the Entry knob to select the LIN standard
you are measuring (LIN 1.3 or LIN 2.0).
Back
60%
70%
80%
Sample Point
One Bit
Summary of Contents for DSO-X 2014A
Page 1: ...Keysight InfiniiVision 2000 X Series Oscilloscopes User s Guide...
Page 8: ...8 Keysight InfiniiVision 2000 X Series Oscilloscopes User s Guide...
Page 60: ...60 Keysight InfiniiVision 2000 X Series Oscilloscopes User s Guide 2 Horizontal Controls...
Page 68: ...68 Keysight InfiniiVision 2000 X Series Oscilloscopes User s Guide 3 Vertical Controls...
Page 118: ...118 Keysight InfiniiVision 2000 X Series Oscilloscopes User s Guide 6 Digital Channels...
Page 124: ...124 Keysight InfiniiVision 2000 X Series Oscilloscopes User s Guide 7 Serial Decode...
Page 130: ...130 Keysight InfiniiVision 2000 X Series Oscilloscopes User s Guide 8 Display Settings...
Page 168: ...168 Keysight InfiniiVision 2000 X Series Oscilloscopes User s Guide 10 Triggers...
Page 176: ...176 Keysight InfiniiVision 2000 X Series Oscilloscopes User s Guide 11 Trigger Mode Coupling...
Page 202: ...202 Keysight InfiniiVision 2000 X Series Oscilloscopes User s Guide 13 Cursors...
Page 226: ...226 Keysight InfiniiVision 2000 X Series Oscilloscopes User s Guide 14 Measurements...
Page 240: ...240 Keysight InfiniiVision 2000 X Series Oscilloscopes User s Guide 15 Mask Testing...
Page 244: ...244 Keysight InfiniiVision 2000 X Series Oscilloscopes User s Guide 16 Digital Voltmeter...
Page 256: ...256 Keysight InfiniiVision 2000 X Series Oscilloscopes User s Guide 17 Waveform Generator...
Page 274: ...274 Keysight InfiniiVision 2000 X Series Oscilloscopes User s Guide 19 Print Screens...
Page 308: ...308 Keysight InfiniiVision 2000 X Series Oscilloscopes User s Guide 21 Web Interface...
Page 326: ...326 Keysight InfiniiVision 2000 X Series Oscilloscopes User s Guide 22 Reference...