Horizontal Controls
Example
This exercise shows a common use of the XY display mode by measuring the
phase difference between two signals of the same frequency with the Lissajous
method.
1
Connect a sine wave signal to channel 1, and a sine wave signal of the same
frequency but out of phase to channel 2.
2
Press the
[AutoScale]
key, press the
[Horiz]
key; then, press
Time Mode
and select
"XY".
3
Center the signal on the display with the channel 1 and 2 position ( ) knobs.
Use the channel 1 and 2 volts/div knobs and the channel 1 and 2
Fine
softkeys
to expand the signal for convenient viewing.
The phase difference angle (
θ
) can be calculated using the following formula
(assuming the amplitude is the same on both channels):
4
Press the
[Cursors]
key.
5
Set the Y2 cursor to the top of the signal, and set Y1 to the bottom of the
signal.
Note the
Δ
Y value at the bottom of the display. In this example, we are using
the Y cursors, but you could have used the X cursors instead.
Figure 3
XY time mode signals, centered on display
sin
θ
=
A
B
or
C
D
A
B
D
C
Signal must
be centered in
“ X”
Measuring
phase difference
Signals 90 degrees
out of phase
Signals
in phase
Summary of Contents for DSO-X 2014A
Page 1: ...Keysight InfiniiVision 2000 X Series Oscilloscopes User s Guide...
Page 8: ...8 Keysight InfiniiVision 2000 X Series Oscilloscopes User s Guide...
Page 60: ...60 Keysight InfiniiVision 2000 X Series Oscilloscopes User s Guide 2 Horizontal Controls...
Page 68: ...68 Keysight InfiniiVision 2000 X Series Oscilloscopes User s Guide 3 Vertical Controls...
Page 118: ...118 Keysight InfiniiVision 2000 X Series Oscilloscopes User s Guide 6 Digital Channels...
Page 124: ...124 Keysight InfiniiVision 2000 X Series Oscilloscopes User s Guide 7 Serial Decode...
Page 130: ...130 Keysight InfiniiVision 2000 X Series Oscilloscopes User s Guide 8 Display Settings...
Page 168: ...168 Keysight InfiniiVision 2000 X Series Oscilloscopes User s Guide 10 Triggers...
Page 176: ...176 Keysight InfiniiVision 2000 X Series Oscilloscopes User s Guide 11 Trigger Mode Coupling...
Page 202: ...202 Keysight InfiniiVision 2000 X Series Oscilloscopes User s Guide 13 Cursors...
Page 226: ...226 Keysight InfiniiVision 2000 X Series Oscilloscopes User s Guide 14 Measurements...
Page 240: ...240 Keysight InfiniiVision 2000 X Series Oscilloscopes User s Guide 15 Mask Testing...
Page 244: ...244 Keysight InfiniiVision 2000 X Series Oscilloscopes User s Guide 16 Digital Voltmeter...
Page 256: ...256 Keysight InfiniiVision 2000 X Series Oscilloscopes User s Guide 17 Waveform Generator...
Page 274: ...274 Keysight InfiniiVision 2000 X Series Oscilloscopes User s Guide 19 Print Screens...
Page 308: ...308 Keysight InfiniiVision 2000 X Series Oscilloscopes User s Guide 21 Web Interface...
Page 326: ...326 Keysight InfiniiVision 2000 X Series Oscilloscopes User s Guide 22 Reference...