83
Option
Description
Rebuild Rate
Choose this option to change the rebuild rate for the controller. You can
also display the firmware version number.
Alarm Control
Choose this option to enable, disable, or silence the onboard alarm tone
generator. Default is disable.
Ultra SCSI
Choose this option to enable or disable Ultra SCSI. Default is disabled.
Auto Rebuild
Choose this option to enable automatic rebuild. Default is enabled.
Logical
Drive
Choose the Logical Drive option from the Objects menu to select a logical drive and to
perform the listed actions.
The following table describes the Logical Drives options.
Option
Description
Initialize
Choose this option to initialize the selected logical drive. This should be
done for every logical drive you configure.
Check
Consistency
Choose this option to verify the correctness of the redundancy data in the
selected logical drive. This option is only available if RAID level 1, 3, or
5 is used.
View/Update
Parameters
Choose this option to display the properties of the selected logical drive;
you can modify the cache write policy, the read policy, and the I/O policy
from this menu.