Page 1: ...H8S 2646 Series FP 144 User System Interface Cable HS2646ECH61H for E6000 Emulator User s Manual HS2646ECH61HE B ...

Page 2: ...of bodily injury such as aerospace aeronautics nuclear power combustion control transportation traffic safety equipment or medical equipment for life support 4 Design your application so that the product is used within the ranges guaranteed by Renesas particularly for maximum rating operating supply voltage range heat radiation characteristics installation conditions and other characteristics Rene...

Page 3: ...esas s original microcomputer H8S 2646 series The HS2646ECH61H is a user system interface cable that connects an H8S 2636 and H8S 2646 series E6000 emulator HS2646EPI61H hereinafter referred to as the emulator to the IC socket for a FP 144 package for the H8S 2646 series MCU on the user system ...

Page 4: ...2 1 Installing IC Socket 5 2 2 2 Inserting Cable Head 6 2 2 3 Fastening Cable Head 7 2 2 4 Fastening Cable Body 9 2 3 Recommended Dimensions for User System Mount Pad 10 2 4 Dimensions for User System Interface Cable Head 11 2 5 Resulting Dimensions after Connecting User System Interface Cable 12 Section 3 Installing the MCU to the User System 13 Section 4 Verifying Operation 15 Section 5 Notice 1...

Page 5: ...cket manufactured by Tokyo Eletech Corporation for the FP 144 package IC socket on the user system Figure 1 shows the configuration of the HS2646ECH61H user system interface cable for the FP 144 package Figure 1 HS2646ECH61H User System Interface Cable 1 ...

Page 6: ...1 Flat cable 2 Cable head 1 3 IC socket 1 For the FP 144 package 4 Socket cover 1 For installing an FP 144 packaged MCU 5 Screws M2 x 10 mm 4 For fastening cable head 6 Screws M2 x 6 mm 4 For installing an FP 144 packaged MCU 7 Guide pins φ 1 mm 3 For determining the IC socket location 8 Screwdriver 1 For tightening screws 9 Documentation 1 User s manual for HS2646ECH61H this manual ...

Page 7: ...ake sure that pin 1 on both sides are correctly aligned 2 The user system interface cable dedicated to the emulator must be used To connect the cable body to the emulator station follow the instructions below 1 Make sure the user system and emulator station are turned off CAUTION When connecting or removing the user system interface cable apply force only in the direction suitable for connection o...

Page 8: ...Emulator station E 6 0 0 0 Cable body connector User system interface cable Figure 2 Connecting User System Interface Cable to Emulator Station 4 ...

Page 9: ...damage the user system and the emulator product or will result in PERSONAL INJURY The USER PROGRAM will be LOST To connect the cable head to the user system follow the instructions below 2 2 1 Installing IC Socket 1 Confirming the location of IC socket CAUTION After confirming the location of pin 1 on the IC socket apply epoxy resin adhesive to the end of the four projections at the bottom of the ...

Page 10: ...IC socket for a FP 144 package to the user system CAUTION Be sure to completely solder the leads so that the solder slops gently over the leads and forms solder fillets Use slightly more solder than the MCU 2 2 2 Inserting Cable Head CAUTION Check the location of pin 1 before inserting Align pin 1 on the IC socket for a FP 144 system interface cable head into the IC socket on the user system as sh...

Page 11: ...ghtening when the force required to turn the screw becomes significantly greater than that needed when first tightening If a screw is tightened too much the screw head may break or an IC socket contact error may be caused by a crack in the IC socket solder 3 If the emulator does not operate correctly cracks might have occurred in the solder Check conduction with a tester and re solder the IC socke...

Page 12: ...ernating between screws on opposing corners Take special care such as manually securing the IC socket soldered area to prevent the soldered IC socket from being damaged by overtightening the screws or twisting the components User system Pin 1 Cable head IC socket NQPACK144SD manufactured by Tokyo Eletech Coporation Screws M2 x 10mm Figure 4 Connecting User System Interface Cable to User System 8 ...

Page 13: ...2 2 4 Fastening Cable Body Connect the cable body to the cable head Cable body Cable head Remove jig Push the remove jig Removing User system Figure 5 Fastening Cable Body 9 ...

Page 14: ...n IC socket for an FP 144 package NQPACK144SD manufactured by Tokyo Eletech Corporation Note that the dimensions in figure 6 are somewhat different from those of the actual chip s mount pad 10 Unit mm Tolerance 0 10 unless otherwise specified 0 50 0 25 max 11 50 23 00 0 15 23 00 0 15 2 00 0 10 11 50 0 50 Figure 6 Recommended Dimensions for Mount Pad ...

Page 15: ...2 4 Dimensions for User System Interface Cable Head The dimensions for the user system interface cable head are shown in figure 7 Figure 7 Dimensions for User System Interface Cable Head 11 ...

Page 16: ...nnecting User System Interface Cable The resulting dimensions after connecting the user system interface cable head to the user system are shown in figure 8 Figure 8 Resulting Dimensions after Connecting User System Interface Cable 12 ...

Page 17: ...uch the screw head may break or an IC socket contact error may be caused by a crack in the IC socket solder 4 If the MCU does not operate correctly cracks might have occurred in the solder Check conduction with a tester and re solder the IC socket if necessary Check the location of pin 1 before inserting the MCU into the IC socket on the user system as shown in figure 9 After inserting the MCU fas...

Page 18: ...MCU Pin 1 IC socket NQPACK144SD manufactured by Tokyo Eletech Corporation User system Screws M2 x 6 mm Socket cover Figure 9 Installing MCU to User System 14 ...

Page 19: ...the user system For details refer to the Emulator Supplementary Information HS2646EPI61HE To use the emulator internal clock Select the clock in the emulator station as the system clock φ by using the CLOCK command emulator command To use the external clock on the user system Select the target clock t or t2 as the system clock φ by using the CLOCK command emulator command Supply the external clock...

Page 20: ...this cable with any other emulator station 4 To prevent breaking of wires in the cable body do not place heavy or sharp metal objects on the user system interface cable 5 While the emulator station is connected to the user system with the user system interface cable force must not be applied to the cable head Place the emulator station user system interface cable and user system as shown in the ex...