73
8. Toggle the Array Encl MGMT I/F option to Enable.
9. Press
ESC
twice to save the automatic rebuild setting.
10. Select Yes to save the configuration.
11. Exit DACCF, remove the diskette, and then restart the system.
Changing the Write Policy
Follow these steps to change the write policy of system drives.
To change the write policy:
1. Ensure the boot sequence for the system is A:, C:.
2. Insert the DACCF diskette into the floppy disk drive.
3. Restart the system.
4. At the command prompt, key in daccf.
5. If you have multiple RAID controller boards installed in the system, select the controller
to be configured.
6. When the DACCF Main Menu displays, select the View/Update Configuration option.
7. Select the Define System Drive option; then, select the Toggle Write Policy option.
8. Use the cursor keys to select a system drive; then, toggle the write policy option to Write
Through or Write Back, as desired.
9. Press
ESC
twice to save the write policy setting.
10. Select Yes to save the configuration.
11. Exit DACCF, remove the diskette, and then restart the system.
Configuring Additional Disk Arrays
Additional disk arrays are not configured at the factory. You can use the quick configuration
process outlined below to configure an additional disk array for RAID Level 5.
To configure for RAID Level 5:
1. If DACCF is already running, go to the DACCF Main Menu. Skip to step 6.
2. Ensure the boot sequence for the system is A:, C:.
3. Insert the DACCF diskette into the floppy disk drive.
4. Restart the system.