33
Use the following table to label the drives:
Disk Drive Label
InterRAID-12 Slots
ADP X CHN 1 ID 6
Slot 12 (Top)
ADP X CHN 1 ID 5
Slot 11
ADP X CHN 1 ID 4
Slot 10
ADP X CHN 1 ID 2
Slot 9
ADP X CHN 1 ID 1
Slot 8
ADP X CHN 1 ID 0
Slot 7
ADP X CHN 0 ID 6
Slot 6
ADP X CHN 0 ID 5
Slot 5
ADP X CHN 0 ID 4
Slot 4
ADP X CHN 0 ID 2
Slot 3
ADP X CHN 0 ID 1
Slot 2
ADP X CHN 0 ID 0
Slot 1 (Bottom)
6. If you have additional cabinets, install the RAID disk drives and complete the drive
label information as appropriate.
Powering On and Configuring the System
To prevent accidental power off or on, the power switch is recessed and not accessible with
the door closed and locked. Before starting the system for the first time, read the following
important operating and software notices.
Important Operating Notices
u
Always power on the InterRAID-12 cabinet and wait for the audible beep before
powering on the system base unit.
u
If you turn off the power to the system base unit before completing the setup procedures,
you must reload the operating system. Once you power on the system base unit, do not
power off the system without completing Windows NT Server installation.
u
Always power off the system base unit before powering off the InterRAID-12 cabinet. If
you power off the cabinet first, the RAID controller board will read the drives as dead
the next time you power on the system. Refer to Chapter 5 “Using DAC InterRAID
Utilities,” or Chapter 6 “Using MegaRAID BIOS” and Chapter 7, “Using Power
Console.”