A05-05x
Description:
Sensor
indicates
an
abnormally
high
internal
temperature.
Action:
Verify
that:
1.
The
room
ambient
temperature
is
within
the
system
operating
environment.
2.
There
is
unrestricted
air
flow
around
the
system.
3.
All
system
covers
are
closed.
4.
There
are
no
fan
failures.
If
none
of
these
problems
exist,
then
proceed
with
“MAP
1230:
Linux
Platform
Error
Problem
Resolution”
on
page
73.
A05-06x
Description:
System
shutdown
due
to
abnormally
high
internal
temperature.
Action:
Verify
that:
1.
The
room
ambient
temperature
is
within
the
system
operating
environment.
2.
There
is
unrestricted
air
flow
around
the
system.
3.
All
system
covers
are
closed.
4.
There
are
no
fan
failures.
If
none
of
these
problems
exist,
then
proceed
with
“MAP
1230:
Linux
Platform
Error
Problem
Resolution”
on
page
73.
A05-07x
Description:
Sensor
indicates
a
power
supply
has
failed.
Action:
Use
“MAP
1230:
Linux
Platform
Error
Problem
Resolution”
on
page
73.
A05-08x
Description:
System
shutdown
due
to
power
supply
failure.
Action:
Use
“MAP
1230:
Linux
Platform
Error
Problem
Resolution”
on
page
73.
A05-09x
Description:
Sensor
detected
a
FRU
that
has
failed.
Action:
Use
“MAP
1230:
Linux
Platform
Error
Problem
Resolution”
on
page
73.
A05-10x
Description:
System
shutdown
due
to
FRU
that
has
failed.
Action:
Use
“MAP
1230:
Linux
Platform
Error
Problem
Resolution”
on
page
73.
A05-14x
Description:
System
shutdown
due
to
power
fault
with
an
unspecified
cause.
Action:
Use
“MAP
1230:
Linux
Platform
Error
Problem
Resolution”
on
page
73.
A05-16x
Description:
System
shutdown
due
to
internal
power
supply
failure.
Action:
Use
“MAP
1230:
Linux
Platform
Error
Problem
Resolution”
on
page
73.
A05-19x
Description:
System
shutdown
due
to
Fan
failure.
Action:
Use
“MAP
1230:
Linux
Platform
Error
Problem
Resolution”
on
page
73.
A05-21x
Description:
System
shutdown
due
to
Over
temperature
condition.
Action:
Verify
the
following:
v
The
room
ambient
temperature
is
within
the
system
operating
environment.
v
There
is
unrestricted
air
flow
around
the
system.
v
All
system
covers
are
closed.
If
all
conditions
are
met,
then
use
“MAP
1230:
Linux
Platform
Error
Problem
Resolution”
on
page
73.
A05-22x
Description:
System
shutdown
due
to
over
temperature
and
fan
failure.
Action:
Use
“MAP
1230:
Linux
Platform
Error
Problem
Resolution”
on
page
73.
A05-24x
Description:
Power
Fault
specifically
due
to
internal
battery
failure.
Action:
Use
“MAP
1230:
Linux
Platform
Error
Problem
Resolution”
on
page
73.
A0D-00x
Description:
Error
log
analysis
indicates
an
error
detected
by
the
Service
Processor,
but
the
failure
could
not
be
isolated.
Action:
Use
“MAP
1230:
Linux
Platform
Error
Problem
Resolution”
on
page
73.
378
Eserver
pSeries
615
Service
Guide
Summary of Contents for P 615 series
Page 1: ...pSeries 615 Service Guide SA38 0630 02 ERserver...
Page 2: ......
Page 3: ...pSeries 615 Service Guide SA38 0630 02 ERserver...
Page 12: ...x EserverpSeries 615 Service Guide...
Page 16: ...xiv EserverpSeries 615 Service Guide...
Page 18: ...xvi EserverpSeries 615 Service Guide...
Page 58: ...38 EserverpSeries 615 Service Guide...
Page 72: ...52 EserverpSeries 615 Service Guide...
Page 150: ...130 EserverpSeries 615 Service Guide...
Page 178: ...158 EserverpSeries 615 Service Guide...
Page 284: ...264 EserverpSeries 615 Service Guide...
Page 384: ...364 EserverpSeries 615 Service Guide...
Page 388: ...Model 6C3Parts 5 5 7 6 6 2 3 1 4 368 EserverpSeries 615 Service Guide...
Page 394: ...374 EserverpSeries 615 Service Guide...
Page 418: ...398 EserverpSeries 615 Service Guide...
Page 422: ...402 EserverpSeries 615 Service Guide...
Page 438: ...418 EserverpSeries 615 Service Guide...
Page 448: ...428 EserverpSeries 615 Service Guide...
Page 452: ...432 EserverpSeries 615 Service Guide...
Page 489: ......
Page 490: ...Printed in U S A October 2003 SA38 0630 02...
Page 491: ...Spine information pSeries 615 EserverpSeries 615 Service Guide SA38 0630 02...